CCD Multichannel Imaging Systems

GaiaSky-VIS/NIR camera provide extremely high-resolution images by scanning and taking multiple images to construct a hyperspectral datacube. Hyperspectral imaging devices (GaiaSky) for lens scanning obtain slit spectra by projecting a strip of the scene onto a slit and dispersing the slit image with a prism or a grating. In ...

Specifications

Number Of Channels: >4
Sensor Type: CCD
Wavelength Range: 400-1000nm
Spectral Resolution: 3.5 nm
Numerical Aperture: F/2.8
GaiaField-Pro (GFP) is a Hyperspectral Imaging Camera. It is capable of providing extremely high resolution images by scanning and taking multiple images to construct a hyperspectral datacube. GaiaField-Pro hyperspectral imaging devices obtain spatial slit spectra by projecting a strip of light from the scene onto a slit and ...

Specifications

Number Of Channels: >4
Sensor Type: CCD
Wavelength Range: 400-1000nm
Spectral Resolution: 3.5 nm
Numerical Aperture: F/2.8
The hyperspectral imager is a light sensor suitable for field operations. Spectral imaging system, the camera has a built-in power module, no need for external wiring, and it can be used on field. Built-in portable hyperspectral imager equipped with laser ranging module and automatic alignment focusing lens, which can quickly ...

Specifications

Number Of Channels: >4
Sensor Type: CCD, CMOS
Wavelength Range: 250-1700nm
Pixel Size: 12um, 17um
Wavelength: 400-1000nm
The Photometrics® QV2™ allows simultaneous acquisition of up to four emission channels in a single exposure. The QV2 uses a series of beam splitters to split the emission light from a microscope into four separate channels. All four channels are projected onto the CCD at the same time. Simultaneous multichannel imaging is critical ...

Specifications

Number Of Channels: 4
Sensor Type: CCD
Wavelength Range: 400-750nm
The Photometrics® DC2™ enables two-channel simultaneous imaging based on two distinct wavelengths or polarizations. Each channel is projected onto an individual CCD. Simultaneous multichannel imaging is essential to achieve quantitative emission ratiometric imaging.

Specifications

Number Of Channels: 2
Sensor Type: CCD
Wavelength Range: 400-750nm
The Photometrics® DV2™ utilizes a single-beamsplitter design to split the emission light from a microscope into two independent channels. Each channel is projected onto half of the CCD at the same time. Simultaneous multichannel imaging is essential for FRET and other emission ratiometric applications.

Specifications

Number Of Channels: 2
Sensor Type: CCD
Wavelength Range: 400-750nm
On FindLight marketplace you will find 6 different CCD Multichannel Imaging Systems from suppliers around the world. With just a few clicks you can compare different CCD Multichannel Imaging Systems and get accurate price quotes based on your needs and quantity required. Note that some wholesale suppliers may offer discounts for large quantities. From any product page you can directly contact any vendor within seconds.