FILTER PRODUCTS

to
to
to
to
to

CCD Beam Profilers

CCD Beam Profiler UV Monitor 10
Hanamura Optics Corp
UV laser beam profiler has a proven track record in industrial applications, and can be used for excimer lasers for processing laser materials in the semiconductor and display industries, and for the 3rd, 4th, and 5th harmonics of Nd: YAG lasers. The basic system of the product consists of a camera based on a detector for UV and ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 157-308nm
# Pixels (Width): --
# Pixels (Height): --
CCD Beam Profiler UV Monitor
Hanamura Optics Corp
UV laser beam profiler has a proven track record in industrial applications, and can be used for excimer lasers for processing laser materials in the semiconductor and display industries, and for the 3rd, 4th, and 5th harmonics of Nd: YAG lasers. The basic system of the product consists of a camera based on a detector for UV and ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 193-1100nm
# Pixels (Width): --
# Pixels (Height): --
CCD Beam Profiler UV Monitor K2
Hanamura Optics Corp
UV laser beam profiler has a proven track record in industrial applications, and can be used for excimer lasers for processing laser materials in the semiconductor and display industries, and for the 3rd, 4th, and 5th harmonics of Nd: YAG lasers. The basic system of the product consists of a camera based on a detector for UV and ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 10-1100nm
# Pixels (Width): --
# Pixels (Height): --
Focus Monitor FM100
Metrolux GmbH
Thanks to its versatility the FM100 is already in use for regular quality control of the laser beam in the display and semiconductor industries as well as in the processing of materials in the automotive industry. In addition to the integrated high power attenuator the FM100 has two filter slots for flexible attenuation of laser ...

Specifications

Sensor Type: CCD
Measurable Sources: Pulsed
Wavelength Range: 248-1100nm
# Pixels (Width): 1388
# Pixels (Height): 1036
Laser Propagation Monitor LPM200
Metrolux GmbH
The exact characterization and specification of laser beam sources is crucial to provide and maintain a high product quality in the laser production. Systems integrators can choose the beam sources to use and integrate according to the parameters defined in the international standard. Metrolux Measurement systems are designed for a ...

Specifications

Sensor Type: CCD
Measurable Sources: Pulsed
Wavelength Range: 340-1100nm
# Pixels (Width): 1388
# Pixels (Height): 1036
Beam Monitor BM8304
Metrolux GmbH
Low S/N ratios and a high sensor response linearity are prime attributes of the sensor employed in this Metrolux beam profiler. The Software provides the functions required for the international standards EN-ISO 11145, 11146, 11670 and 13694 that cover aspects of laser light characterization. The beam profiler camera BPC8304 uses a ...

Specifications

Sensor Type: CCD
Measurable Sources: Pulsed
Wavelength Range: 340-1100nm
# Pixels (Width): --
# Pixels (Height): --
XRV-2000 Falcon Camera Phantom
Logos Systems
The XRV-2000 Falcon Beam Profiler combines high-energy radiation detection with precision two dimensional metrology to form a completely electronic alternative to film-based measurements. The XRV-2000 Falcon measures the XY location and profile of radiation beams with unmatched speed and accuracy. Single beams and proton energy layer ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 0.01-10nm
# Pixels (Width): 1280
# Pixels (Height): 960
XRV-100 Digital Camera Phantom
Logos Systems
The XRV family of X-ray and proton beam inspection systems combines precision metrology with high-energy radiation detection to form a completely electronic alternative to film-based measurements. The XYZ location and vector of pencil-thin beams of radiation can now be measured with unmatched speed and accuracy. Beam vector, profile ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 0.01-10nm
# Pixels (Width): 1280
# Pixels (Height): 960
XRV-124 Detector Phantom
Logos Systems
The XRV family of X-ray and proton beam inspection systems combine precision metrology with high-energy radiation detection to form a completely electronic alternative to film-based measure-ments. The XYZ location and vector of pencil-thin beams of ionizing radiation can now be measured with unmatched speed and accuracy. Beam vector, ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 0.01-10nm
# Pixels (Width): 1280
# Pixels (Height): 960
LPM200 – Laser Propagation Monitor 200
Metrolux GmbH
The LPM200 is designed for the automated determination and monitoring of lasersand the beam parameters of laser beams with long Rayleigh lengths where standard beam profilers do not provide sufficient functionalities. The LPM200 system includes an optical system for imaging the laser beam caustic as well as a linear stage to scan ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 340-1100nm
# Pixels (Width): 1388
# Pixels (Height): 1036
FM100 – Focus Monitor 100
Metrolux GmbH
Thanks to its versatility the FM100 is already in use for regular quality control of the laser beam in the display and semiconductor industries as well as in the processing of materials in the automotive industry. In addition to the integrated high power attenuator the FM100 has two filter slots for flexible attenuation of laser ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 248-1100nm
# Pixels (Width): 1388
# Pixels (Height): 1036
BM8304 - Beam Monitor 8304
Metrolux GmbH
Low S/N ratios and a high sensor response linearity are prime attributes of the sensor employed in this Metrolux beam profiler. The Software provides the functions required for the international standards EN-ISO 11145, 11146, 11670 and 13694 that cover aspects of laser light characterization. The beam profiler camera BPC8304 uses a ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 340-1100nm
# Pixels (Width): 1392
# Pixels (Height): 1040
The µBeam HP is a beam diagnostics measurement system for real-time measurement and display of small CW or pulsed lasers in the sub-micron range, fiber optic and laser diode beam profiles. Main features include: measure beam of less than 0.5µm (FWHM), handles CW or pulses, having a long working distance, using a high resolution ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 350-1310nm
# Pixels (Width): 1040
# Pixels (Height): 1392
Duma\'s High Power Laser Measuring Device is a robust all-in-one instrument with built-in state-of-the-art air-cooled beam dump, operating from 350 - 1600 nm lasers. It will measure M², BPP (Beam Propagation Parameters), Beam size at its focal position down to less than 100 microns. A unique feature allows measurement of ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 350-1310nm
# Pixels (Width): 1040
# Pixels (Height): 1392
The LAT (Laser Analyzing Telescope) is a powerful measuring instrument enabling direct measurement of laser beams or other light sources. The LAT will analyze and display the angular direction of incoming laser beams with resolutions down to 1 micro-radian and accuracy of 1 millidegree (~20 micro-radian). The built-in back ...

Specifications

Sensor Type: CCD
Measurable Sources: CW
Wavelength Range: 350-1600nm
# Pixels (Width): 1040
# Pixels (Height): 1392
The BeamOn HR system is a beam diagnostics measurement system for real-time measurement of CW or Pulsed laser beams. It provides laser beam parameters, such as: beam width, shape, position, power, and intensity profiles. Software also provides report function for beam analysis settings and results (see an example on Downloads).

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 350-1310nm
# Pixels (Width): 576
# Pixels (Height): 750
BeamOn Long-Bow is a measurement station composed of a CCD type beam profiler, supplemented with high magnification optics and computing technology. This is a powerful beam diagnostics measurement system for real-time measurement and display of CW or pulsed lasers. The system is an imaging beam profiler for examining reflected ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 350-1310nm
# Pixels (Width): 1200
# Pixels (Height): 1920
The µBeam is a beam diagnostics measurement system for real-time measurement and display of small CW or pulsed lasers in the sub-micron range, fiber optic and laser diode beam profiles. Main features include: measure beam of less than 0.5µm (FWHM), handles CW or pulses, having a long working distance, using a high resolution CCD ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 350-1310nm
# Pixels (Width): -
# Pixels (Height): -
Complete system for Laser Beam Analysis, composed of a CCD camera head, a set of 3xNG Schott colored filters (NG4, NG9, NG10) in housing, a USB 2.0 attachment, software on CD disk, carrying case, user manual. The BeamOn system is a beam diagnostics measurement system for real-time measurement of continuous or pulsed laser beams. It ...

Specifications

Sensor Type: CCD
Measurable Sources: CW, Pulsed
Wavelength Range: 190-1310nm
# Pixels (Width): 720
# Pixels (Height): 576
On FindLight marketplace you will find 19 different CCD Beam Profilers from suppliers around the world. With just a few clicks you can compare different CCD Beam Profilers and get accurate price quotes based on your needs and quantity required. Note that some wholesale suppliers may offer discounts for large quantities. From any product page you can directly contact any vendor within seconds.