XRV-2000 Falcon Camera Phantom
Description
The XRV-2000 Falcon Beam Profiler combines high-energy radiation detection with precision two dimensional metrology to form a completely electronic alternative to film-based measurements. The XRV-2000 Falcon measures the XY location and profile of radiation beams with unmatched speed and accuracy. Single beams and proton energy layer patterns up to 19 x 19 cm in size may be directed at the scintillator surface from vertical and horizontal orientations for measurement. Automation scripts can be used to capture changes in the beam shape, intensity, and location over time. XRV systems calibrate proton and radiosurgery systems or industrial radiation sources that must deliver precise amounts of radiation to targeted regions in 3D space. The correct operation of pencil beam scanning or mechanical leaf collimators used in these systems can be quickly verified. Beam FWHM diameter measurements are accurate to +-0.1 mm and centroid positions to +-0.2 mm. Beam viewing software enables real-time any-angle viewing of the captured profile data with live penumbra and symmetry-style measurements. Captured images can be exported to ImageJ or other image analysis software. All operations are controlled by a laptop or desktop PC supplied with the camera phantom. The XRV comes with a 30 meter (100 feet) USB3 power-over-fiber extender cable so that the system PC and operator can be located safely away from the radiation source. The digital camera phantom weighs approximately 3.5 kilograms (7.7 pounds) and is stored in the Pelican case provided as part of the system.
XRV-2000 Falcon Camera Phantom
Specifications |
|
---|---|
Sensor Type: | CCD |
Measurable Sources: | CW, Pulsed |
Wavelength Range: | 0.01-10nm |
# Pixels (Width): | 1280 |
# Pixels (Height): | 960 |
Pixel Size (Width): | -- um |
Pixel Size (Height): | -- um |
Max Full Frame Rate: | 30 Hz |
ADC: | 8-bit, 12-bit |
Features
Proton and X-ray beam Quality Assurance
Real-time 200 x 200 mm beam profile and position capture
360 degree rotation with optional Gantry Cradle
Effective Resolution 0.22 mm at 8 or 12-bits per pixel
Flexible scintillator, fiducial, wedge, and build-up options
BeamWorks Strata software includes GUI or script operation
Individual or integrated frame capture modes
Advanced beam profile viewing and measurements
Statistical analysis macros for easy export to spreadsheets
Proton range verification using optional LCW-200 or LCW-375
For pricing, technical or any other questions please contact the supplier
- No registration required
- No markups, no fees
- Direct contact with supplier
-
Ships from:
United States
-
Sold by:
-
On FindLight:
External Vendor
Claim Logos Systems Page to edit and add data
Frequently Asked Questions
The beam FWHM diameter measurements are accurate to +-0.1 mm.
The effective resolution of the XRV-2000 Falcon Beam Profiler is 0.22 mm at 8 or 12-bits per pixel.
The digital camera phantom weighs approximately 3.5 kilograms (7.7 pounds).
The XRV-2000 Falcon Beam Profiler is used for measuring the XY location and profile of radiation beams with unmatched speed and accuracy.
The XRV-2000 Falcon Beam Profiler comes with BeamWorks Strata software, which includes GUI or script operation.