FILTER PRODUCTS

to
to

Page 2 - No cooling Power Sensors

PROLITE-63B Low Cost Optical Power Meter
Promax Electronica
The PROLITE-63B is a functional and intelligent optical power meter. Under the situation of laboratory, LANs, WANs and CATV as well as long distance optical network, the optical power meters, together with PROMAX LASER sources can be used to identify optical fiber, measure optical attenuation, verify continuity and evaluate fiber ...

Specifications

Max Average Power: -- W
Effective Aperture: -- mm
Spectral Range: 0.85-1.625um
Cooling Method: No cooling
PROLITE-17 Pocket Optical Meter
Promax Electronica
The PROLITE-17 pocket-sized optical power meter has compact structure and stable performance. It ensures high measuring precision of 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm and 1625 nm wavelengths. PROLITE-17 is ideal to be carried out at any time.  

Specifications

Max Average Power: -- W
Effective Aperture: -- mm
Spectral Range: 0.85-1.625um
Cooling Method: No cooling
Model 358 UV Light & Intensity Energy Meters For High Intensity Steppers
OAI
This instrument is designed for use with the ASML High Intensity, Canon, Nikon, and Ultratech High Intensity Wafer Steppers. The microprocessor based Model 358 UV Light Intensity & Energy Meter performs measurement, storage and recall of nine series of readings. Reads intensity, energy, and time (4000 mW/cm², 999.9 mJ/cm²) for ...

Specifications

Max Average Power: 4 W
Effective Aperture: -- mm
Spectral Range: 0.356-0.436um
Cooling Method: No cooling
Model 357 UV Light Intensity & Energy Meter For Wafer Steppers
OAI
Designed for use with ASML, Nikon, Canon, GCA & Rudolph Technology Wafer Steppers, the Model 357 UV Light Intensity & Energy Meters is a microprocessor based instrument that performs measurement, storage, and recall of nine series of readings. It reads intensity, energy, and time (16-1600 mW/cm², 999.9 mJ/cm²x). For 400 and ...

Specifications

Max Average Power: 1.6 W
Effective Aperture: -- mm
Spectral Range: 0.365-0.540um
Cooling Method: No cooling
Model 308T Handheld UV High Intensity Light Meter
OAI
Built for high intensity applications the NEW OAI Model 308T UV Light Meter is a dependable, direct-reading instrument designed for measuring UV light intensity for UV curing. The Model 308T features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port. Accuracy of the meter is within ±3%and ...

Specifications

Max Average Power: -- W
Effective Aperture: -- mm
Spectral Range: 0.365-0.540um
Cooling Method: No cooling
Relative Accuracy 275-2000 Mw/cm2 Range: ±(.042% of reading +.450 mw/cm2 )
Model 308 Handheld UV Light Meter
OAI
Dependable and repeatable, The OAI Model 308 UV Light Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data ...

Specifications

Max Average Power: -- W
Effective Aperture: -- mm
Spectral Range: 0.365-0.540um
Cooling Method: No cooling
Relative Accuracy 275-2000 Mw/cm2 Range: ±(.042% of reading +.450 mw/cm2)
Absolute power sensing of laser beams up to 50 W Highly sensitive thermopile sensor Sensitive to all wavelengths from UV to MIR 200 ms rise time Compact and robust design for system integratio

Specifications

Max Average Power: 50 W
Effective Aperture: 26 mm
Spectral Range: 0.19-15um
Cooling Method: No cooling