Interferometers

MESO metrology system is a one-stop solution to many challenges in optical metrology. Shop floor measurements ensure quality control testing and in situ process control of your flat optics right next to the manufacturing line. A unique instrument allows to measure at several different wavelengths with no chromatic abberrations and ...

Specifications

Interferometer Configuration: Not Specified
Light Source: 1064nm
Output Polarization: Linear, Circular
RMS Repeatability: Not Specified
RMS Precision: Not Specified
The Optical Engineer Companion is an optical metrology system comprising compatible and complementary optical hardware, software and accessories. It spans 800+ combinations and covers a wide range of uses and applications. The Companion’s modularity and clever design enable snap reconfigurations to switch between setups and ...

Specifications

Interferometer Configuration: Not Specified
Light Source: 1550nm
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Kaleo Kit is a modular system for optics qualification. It combines a broad range of compatible modules, that let you create a cost-effective, compact, and easy-to-use system that can adapt to a wide range of measurement configurations and ensure the quality of your sample at all development stages. Access all the characteristics of ...

Specifications

Interferometer Configuration: Not Specified
Light Source: 543nm, 594nm, 632 nm or 633nm, 1550nm, 1064nm, 1053nm, 780nm, 532nm, 355nm
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Phasics is innovating in optical metrology with a new instrument able to measure both transmitted and reflected wavefront error (TWE/RWE). Coated and uncoated optics can be qualified over a diameters from 30 to 150 mm at their working wavelengths. The Kaleo MultiWAVE is an advantageous alternative and cost-effective solution to the ...

Specifications

Interferometer Configuration: Not Specified
Light Source: 543nm, 594nm, 632 nm or 633nm, 1550nm, 1064nm, 1053nm, 780nm, 532nm, 355nm
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
FiBO® 200 Interferometer is an economical solution for complete and accurate fiber optic connector end-face testing. High resolution 3D surface metrology and automated defect detection are combined in one robust, compact system for quick and easy inspection on the production floor or in the field.

Specifications

Interferometer Configuration: Michelson Interferometer
Light Source: 532nm, 355nm
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
M-WAVE 339 MWIR Interferometer
M3 Measurement Solutions
The M-Wave 339 Infrared Interferometer is a state of the art LUPI (Laser Unequal Path Interferometer) operating at 3.39 micrometers. It is the ideal instrument for testing mid-wave infrared imaging components/systems and optical material homogeneity.

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Linear
RMS Repeatability: <0.001 waves
RMS Precision: <0.01 waves
Interferometer SP 5000 TR
PE Schall GmbH & Co KG
Many applications in industry and research require high-precision simultaneous displacement and angle measurements. Fast set-up and easy adjustment are particularly important.Triple-beam laser interferometers are precision length measuring devices that combine three interferometers in one device. The same highly stable laser ...

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Linear
RMS Repeatability: Not Specified
RMS Precision: Not Specified
QED Inteferometer for Stitching QIS
QED Technologies Inc
The QIS interferometer completely designed, engineered and built by QED Technologies. It is optimized for stitching and gives customers the ability to measure more parts, with improved accuracy, speed and ease of use. QED’s QIS incorporates hardware and software features designed to enhance the performance of QED’s metrology ...

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Solid Etalons
TecOptics Corp
Solid Etalons typically have fused silica substrates with the material grade (e.g. UV-visible or IR) dependent on the spectral region. The faces are ground, polished, and figured typically to better than l/100 flatness with similar quality parallelism between the faces. Dielectric (or, rarely, metallic) coatings provide the ...

Specifications

Interferometer Configuration: Not Specified
Light Source: N/A
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: <0.01 waves
Air-Spaced Etalons
TecOptics Corp
Air-Spaced Etalons have appropriate grade fused silica (UV-visible or IR) substrates. Outside-face AR coatings and wedges on the substrates prevent extraneous interference patterns from forming. Spacers, optically contacted to the substrates, determine the parallelism of the mirrored surfaces and the etalon’s free spectral ...

Specifications

Interferometer Configuration: Not Specified
Light Source: Not Specified
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: <0.01 waves
MicroEtalons
TecOptics Corp
Fiber optic communication requires extreme miniaturization of optical components. It is for applications such as DWDM (dense wavelength division multiplexing), line narrowing, and channel monitoring that TecOptics introduced its new line of MicroEtalons. Newly developed manufacturing techniques enable TecOptics to supply large ...

Specifications

Interferometer Configuration: Not Specified
Light Source: 632 nm or 633nm, 355nm, 532nm, 780nm, 1053nm, 1064nm, 1550nm, 10.6um, 543nm, 594nm
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: <0.01 waves
Interferometer VI-vario 10
Vermont Photonics Technologies Corp
Interferometers are an indispensable measurement tool in optical production and quality control. They are used for a wide variety of applications. Examples are testing of flatness and sphericity of optical surfaces, radius measurement and the testing of the wavefront of optical systems. The interferometers of the VI series are ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: Not Specified
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Interferometer VI-direct SL 10
Vermont Photonics Technologies Corp
Interferometers are an indispensable measurement tool in optical production and quality control. They are used for a wide variety of applications. Examples are testing of flatness and sphericity of optical surfaces, radius measurement and the testing of the wavefront of optical systems. The interferometers of the VI series are ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: Not Specified
Output Polarization: N/A
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Interferometer VI-direct 10
Vermont Photonics Technologies Corp
Interferometers are an indispensable measurement tool in optical production and quality control. They are used for a wide variety of applications. Examples are testing of flatness and sphericity of optical surfaces, radius measurement and the testing of the wavefront of optical systems. The interferometers of the VI series are ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: Not Specified
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Verifire HDX Interferometry For Precise Mid-Spatial Frequency Characterization
Zemetrics
ZYGO\'s new Verifire HDX interferometer is designed and built for mid-spatial frequency content characterization of extreme performance optical components and systems. The system includes all the great features of the popular Verifire HD – such asQPSI, and a long-life stabilized laser – and adds important enhancements ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: Not Specified
Output Polarization: Circular, Elliptical, Random
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Verifire HD Interferometer System
Zemetrics
ZYGO\'s Verifire™ HD interferometer system provides fast high-resolution measurements of flat or spherical surfaces, and transmitted wavefront measurement of optical components and assemblies. The interferometric cavity length is precisely modulated while a high-speed camera captures several fringe images, which are analyzed by ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: Not Specified
Output Polarization: Circular, Elliptical, Random
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Verifire Fizeau Interferometer
Zemetrics
ZYGO\'s Verifire™ interferometer system provides fast high-precision measurements of plano or spherical surfaces, and transmitted wavefront ofoptical systems and assemblies. Measure glass or plastic optical components – like flats, lenses, and prisms – and even precision machined metal and ceramic surfaces.A true ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: Not Specified
Output Polarization: Circular
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Newly available from Armstrong Optical are a range of customer-proven phase-measuring Fizeau interferometers with 300mm (12”) aperture in both vertical (downward-looking) and horizontal configurations, IFV-300 and IFH-300. Both configurations are supplied with a certified lambda/20 transmission flat and an ergonomically designed ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: White Light
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified
Newly available from Armstrong Optical is a customer-proven phase-measuring Fizeau interferometer with 60mm aperture in a vertical (downward-looking) configuration, IFV-60. The aperture can also be increased to 100 if required. It is supplied with a certified lambda/20 transmission flat and an ergonomically designed sample handling ...

Specifications

Interferometer Configuration: Fizeau Interferometer
Light Source: White Light
Output Polarization: Linear
RMS Repeatability: Not Specified
RMS Precision: Not Specified
FiBO® 300 is a versatile phase-shifting interferometer for the analysis of fiber optic endface geometry. Measure non-standard, angle-polished and cleaved bare optical fiber with just one click. FiBO makes sophisticated interferometry easy and affordable.

Specifications

Interferometer Configuration: Michelson Interferometer
Light Source: 355nm, 532nm
Output Polarization: Not Specified
RMS Repeatability: Not Specified
RMS Precision: Not Specified

Frequently Asked Questions

An interferometer is an optical metrology tool that measures the difference in distance between two surfaces with high accuracy and precision. It is commonly used in industries such as semiconductor manufacturing, optics, and aerospace.

Interferometers work by splitting a light beam into two separate beams and then recombining them to form an interference pattern. The pattern changes based on the distance between the surfaces being measured, allowing for high-precision measurement of changes in distance.

Interferometers offer high accuracy and precision in measuring distances, making them ideal for use in industries where precise measurements are critical. They are non-contact, which means they can be used to measure delicate or fragile surfaces without causing damage. Additionally, interferometers can measure distances over long ranges, making them useful for large-scale measurements.

Interferometers are used in a variety of industries, including semiconductor manufacturing, optics, and aerospace. They are commonly used for surface metrology, including the measurement of surface flatness, surface roughness, and surface deformation. Interferometers are also used for the calibration of other instruments, such as coordinate measuring machines (CMMs) and scanning electron microscopes (SEMs).

When choosing an interferometer, it is important to consider factors such as accuracy, measurement range, and compatibility with the materials being measured. It is also important to choose an interferometer with the appropriate wavelength range and sensitivity for the application. Additionally, the sample stage must be compatible with the sample being measured. Some interferometers also offer additional features, such as vibration isolation and environmental controls.

There are several types of interferometers, including Michelson, Mach-Zehnder, and Fabry-Perot interferometers, among others. Each type has its own unique configuration and is suited for different applications. For example, the Michelson interferometer is commonly used for measuring wavelength and distance, while the Fabry-Perot interferometer is used for measuring the spectral characteristics of light.

Interferometers have some limitations, such as sensitivity to vibration and temperature changes. To overcome these limitations, interferometers can be equipped with vibration isolation and environmental controls. Additionally, interferometers may have limited measurement ranges or may require specialized sample stages for specific applications. It's important to choose an interferometer that is suited for the specific application and that can provide the required accuracy and precision.

There are 25 different Interferometers from suppliers and manufacturers listed in this category. In just a few clicks you can compare different Interferometers with each other and get an accurate quote based on your needs and specifications. Please note that the prices of Interferometers vary significantly for different products based on various factors including technical parameters, features, brand name, etc. Please contact suppliers directly to inquire about the details and accurate pricing information for any product model. Simply navigate to the product page of interest and use the orange button to directly reach out to the respective supplier with one click.

Did You know?

Did you know that interferometers are essential optical metrology tools for measuring the distance between two surfaces with high accuracy and precision? Interferometers work by splitting a light beam into two separate beams and then recombining them to form an interference pattern, which changes based on the distance between the surfaces being measured. These instruments are widely used in various high-tech industries, such as semiconductor manufacturing, optics, and aerospace, for surface metrology applications, including the measurement of surface flatness, roughness, and deformation. Interferometers are non-contact, non-destructive, and capable of measuring distances over long ranges, making them ideal for measuring delicate or fragile surfaces without causing damage. When choosing an interferometer, it's important to consider factors such as accuracy, measurement range, wavelength range, sensitivity, and compatibility with the materials being measured. Interferometers can also offer additional features, such as vibration isolation and environmental controls, to enhance their functionality in various applications.