The EX-5100 Catalytic Combustible Gas Sensor is used for remote gas monitoring.

The sensor uses a pellistor or catalytic bead sensor. It consists of a matched pair of elements, one active and the other for compensation. The active bead is coated with a catalyst that causes the gas or vapor to oxidize at concentrations below the Lower Explosive Limit (LEL). This oxidization process raises the temperature of the active bead and increases the resistance of the internal wire coil.

The transmitter provides a 4-20 mA output signal that can be connected to a controller, PLC, or similar instrumentation.

Yes, the EX-5100 can be calibrated for over 30 different combustible hydrocarbons and solvents. ENMET can also generate calibration data for most common combustible gases and vapors for which a sample can be readily obtained.

Yes, the EX-5100 is approved for Class I, Division 1, Groups B, C & D and has a NEMA 4X, NEMA 7, and IP66 rated enclosure.